Chlorinator Well Water Proportional Feed 1-1/2" J-PRO-22 110-240V

Chlorinator Well Water Proportional Feed 1-1/2" J-PRO-22 110-240V
Processing...
Code: CS000670

$1,255.00 $2,271.00 List Price


In Stock!


Overview

Easy Set Up Automatic Chlorinator for Your Well Water

Easy Installation! No-Wiring Needed! Plug into any 110V to 240V wall outlet, and when there is flow, the J-PRO-22 Metering Pump will instantly and accurately inject the precise amount of chlorine (or other chemicals) based on the flow rate of the water!

Package includes Dual Voltage J-PRO-22 Electronic Digital Pulse Metering Pump, 1-1/2" CWS Lead-Free Flow Sensor with Cable, & Heavy-Duty Solution Tank, injection check valve, tubing, fitting.Fat Shipping.

Our J-PRO-22 series proportional-feed chlorinators are the best way to achieve accurate chlorine residuals with the least amount of maintenance. This chlorinator system injects the precise amount of chlorine required based on the flow of the water. System is fully automatic and pumps more or less chlorine based on flow rate!


Read Full Description


  • Description
  • Specs
  • Warranty
  • Info
  • Documents


Versatile Chlorinator Works for a Wide Range of Conditions and Wells:

  • CWS Lead-Free heavy-duty nylon engineered plastic flowmeter with unions, accurate metering at even low flow rates.
  • Good for chlorinating well water flow rates from 0.5 to 20 gallons per minute
  • Metering pump can deliver up to 22 gallons of chlorine solution per day.
  • Metering pump is easily adjustable to get just the right chlorine residual that is needed.
  • Works for line pressures up to 100 PSI
  • Dimensions: 5 gallon model: 10" x 10" x 15", height including pump is 26"
  • Dimensions: 15 gallon model: 14.5" wide x 24", height including pump is 35".
  • Dimensions: 35 gallon model: 18" wide x 33", height including pump is 44".
  • Dosage is controlled by the flow sensor as well as digital controls on pump
  • De-gassing vent built-in makes the pump great for chlorination use
  • Unlike Stenner-style peristaltic pumps: no pump tube failures, no rollers to go bad, needs less service, and good for continuous duty
  • Uses regular household bleach (5% sodium hypochlorite) or liquid pool chlorine (12% sodium hypochlorite)
  • These heavy-duty metering pumps systems are designed to last for many years with minimal maintenance.
  • Pump easily mounts on the top of the tank or a wall
  • Primes super fast, and won't lose its prime.
  • Complete system includes chlorinator pump, solution tank, injection check valve, tubing, fittings
  • Easy and fast to install!
  • Dual Voltage! Works out of the box with 110v to 240V 50/60hz. 
  • Uses only 22 watts (0.2 amps) of power when operating.





  • Each System Includes:

  • J-PRO-22 Home Well Water Digital Pulse Chlorinator Pump with 5, 15 or 35 gallon heavy-duty polyethylene (HDPE) solution tank
  • CWS Lead-Free  heavy-duty nylon engineered plastic pulse flow meter and cable.
  • Tubing and fittings to connect pump to injection check valve
  • Injection Check valve 1/2" NPT
  • Easy to read Manual
  • Professional Tech Support from WQA Water Specialists if you have any questions
  • What size solution tank should I order?

  • We recommend the 5 or 15 gallon tank. 
  • There is usually no home well water application where the 35 gallon tank is needed.
  • Most of our customers use 2 - 5 gallons of chlorine solution per month.
  • There is no advantage to using a larger solution tank in most cases because the chlorine can/ will go bad, after a couple of months.
  • Mix up enough fresh chlorine solution to last for 3 months as chlorine can lose its strength over time.

  • How much space is required to install the system?

  • Flow meter including the built-in unions is 15" long and requires 15 to 16" of horizontal pipe length.
  • The injection check valve (where the chlorine solution is injected) is 1/2" male pipe thread and only requires a PVC tee.
  • The solution tanks sit on the floor and are either 14.5", 15.8" or 18" depending on size you select.

  • What type of bleach should I use?

  • You can use liquid bleach as long as it is only sodium hypochlorite with no additives.
  • Some areas have HASA brand liquid bleach which is NSF certified for drinking water
  • Do not use household laundry bleach, as it contains additives
  • We recommend using NSF Certified Chlorine Powder which has no additives or contaminants
  • To use just add 1 oz of powder to 1 gallon of soft or purified water to make up your solution
  • 1 5-lb jug is more than enough chlorine for most residential well applications for 8 to 12 months
  • Stores for up to 8 to 12 months in cool, dark, dry location.
  •  

    Pulse Flow Meter Features:

  • Totalizing meter with pulse output for precise proportional feed of chlorine, peroxide, soda ash and other chemicals.
  • Multi-jet magnetic drive is precise and accurate. 
  • Vacuum sealed register prevents fodding and moisture build-up.
  • Rugged meter housing constructed of reinforced black nylon
  • Register: U.S. gallons. Pulse Output: 1 pulse per gallon
  • Pulse type: Reed switch (dry contacts) 1 gallon/pulse 

  • Pulse Flow Meter Specifications:

  • Pressure rating: Min. 15 PSI. Max 100 PSI
  • Dimensions: 14.5" x 4" x 4.5"
  • Maximum Pressure: 100 PSI
  • Temperature: Minimum 35F Maximum 105F
  • Pipe connectors: NPT and/or BSP (NPT standard)
  • Part numbers: 3/4" Meter: M7001380 1" M7001390
  • Flow: 1": 0.8 to 50 GPM 3/4": 0.5 to 22 GPM




  • Free Expert Technical Set-up & Support:

    We can offer you expert advice on the exact type of chlorine solution to use, how much to use and what settings to use with your new chlorinator. These pumps are the easiest and most accurate chlorinator pumps available on the market today. Loaded with features only found in much more expensive industrial metering pumps, our J-PRO-22 Metering Pump makes chlorine and other chemical injection fast and accurate. Our easy-to-use installation guide will guide you through the steps, but if you need help or have questions, we are just a phone call or email away.






    Sizing Guide:

    Flow Rate Comparison Chart in Gallons Per Minute
    Model
    Minimum Flow Rate
    Maximum Flow Rate
    3/4" Model
    0.520
    1" Model
    131
    1-1/2" Model
    189


    Specifications:

  • Uses 5% grade liquid bleach or 12% liquid pool chlorine
  • Good for chlorinating well water flow rates from 1 to 50 Gallons Per Minute (1 - 50 GPM)
  • Pumps 0.1 to 22 gallons of solution per day
  • Works for line pressures up to 110 PSI
  • 110v OR 220v inlcuded. Dual voltage. No need to specify 110V or 220V, works on either voltage.
  • Uses only 22 watts of power.
  • Dimensions: 5 gallon model: 10" x 10" x 15", height including pump is 26"
  • Dimensions: 15 gallon model: 14.5" wide x 24", height including pump is 35".
  • Dimensions: 35 gallon model: 18" wide x 33", height including pump is 44".
  • Digital speed adjustment makes adjusting the pump fast and easy for incredibly accurate injection
  • 1 Year Warranty from date of delivery.

    1 Year Warranty. 90 Day Money Back Guarantee. We guarantee it works great for you or your money back.  If your pump fails under warranty, please call or email our office to obtain a Returns Good Authorization Number before sending us back the pump for repair or replacement under the warranty. No returns can be accepted without an RGA number.

    The Warranty covers repair and/or replacement of the metering pump but not shipping costs.

    While defects are rare, we do our best to respond to warranty returns fast as we can. Please allow 3 to 5 business days after pump has been returned for your pump to be repaired or a new one supplied under the warranty agreement.
     
    If the water supply and its continuous chlorination are critical, a back-up chlorinator pump should be on hand. Shipping charges are not covered under warranty.. Any expedited shipping (overnight, 2-day, etc.) is the customer's responsibility.
     

    Conditions Not Covered by the Warranty:

    Power surges or outages that cause pump failure are not covered under warranty.

    Surge protection is strongly recommended. If a pump is returned for warranty replacement and the cause of failure is determined to be from a voltage spike, the pump does not qualify for replacement. This is the leading cause of failure. Pump failure during, or because of, power failure is not covered under warranty.    
     
    This pump is intended for indoor use only. The pump must never be exposed to freezing temperatures, direct sunlight, or rain. If the cause of failure is determined to be from exposure to any of these environments, the pump does not qualify for replacement and will not be covered under warranty. 
     

    Manufacturer: CWS

    Manufacturer #: CS000670

    Download Installation Guide

    Specification Sheet


    Reviews